Alarm Handling

S600-E V200R010C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ENTITYTRAP_1.3.6.1.4.1.2011.5.25.219.2.2.3 hwBoardFail 132146

ENTITYTRAP_1.3.6.1.4.1.2011.5.25.219.2.2.3 hwBoardFail 132146

Description

ENTITYTRAP/2/BOARDFAIL: OID [oid] Board become failure for some reason. (Index=[INTEGER], EntityPhysicalIndex=[INTEGER], PhysicalName="[OCTET]", EntityTrapEntType=[INTEGER], EntityTrapFaultID=[INTEGER], EntityTrapReasonDescr="[OCTET]")

Some functions on the board did not take effect.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.219.2.2.3 Major equipmentAlarm(5)

Parameters

Name Meaning
OID Indicates the ID of the MIB object.
Index Indicates the index.
EntityPhysicalIndex Indicates the physical index.
PhysicalName Indicates the entity name.
EntityTrapEntType Indicates the entity type.
EntityTrapFaultID Indicates the error code.
EntityTrapReasonDescr Indicates the description of the alarm cause.

Impact on the System

The board may be unavailable, some functions on it did not take effect, and services may be interrupted.

Possible Causes

The Power over Ethernet (PoE) was faulty.

Procedure

  1. Replace the faulty PoE power.

    If the fault persists, go to step 2.

  2. Replace the faulty PoE DIMM.

    If the fault persists, go to step 3.

  3. Collect alarm information and configuration information, and then contact technical support personnel.