Alarm Handling

S600-E V200R010C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
SRM_1.3.6.1.4.1.2011.5.25.129.2.17.1 hwOpticalPowerAbnormal 136195

SRM_1.3.6.1.4.1.2011.5.25.129.2.17.1 hwOpticalPowerAbnormal 136195

Description

SRM/3/RXPOWER_EXCEEDMAJOR:OID [oid] Optical module exception, Rx power is too high. (EntityPhysicalIndex=[INTEGER], BaseTrapSeverity=[INTEGER], BaseTrapProbableCause=[INTEGER], BaseTrapEventType=[INTEGER], EntPhysicalContainedIn=[INTEGER], EntPhysicalName=[OCTET], RelativeResource=[OCTET], ReasonDescription=[OCTET])

The receive power of an optical module is too high.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.129.2.17.1 Minor equipmentAlarm(5)

Parameters

Name Meaning
OID Indicates the ID of a MIB object.
EntityPhysicalIndex Indicates a physical entity index.
BaseTrapSeverity Indicates the alarm severity.
BaseTrapProbableCause Indicates the error code of the alarm.
BaseTrapEventType Indicates the event type.
EntPhysicalContainedIn Indicates contained physical entity code.
EntPhysicalName Indicates the physical entity name.
RelativeResource Indicates a sub-entity.
ReasonDescription Describes reason of the fault.

Impact on the System

This alarm does not affect system operating if the interface on which the optical module is installed works properly.

Possible Causes

The receive power is too high.

Procedure

  1. Run the display transceiver slot slot-id verbose command in the system view to check whether the receive power Rx Power of the optical module is within the allowed range. If so, collect alarms, logs, and configurations, and contact technical support personnel.
  2. Check whether an alarm is generated for high transmit power on the peer optical module. If so, rectify the peer optical module fault first.
  3. Check whether the peer optical module and the local optical module are of the same type. If not, replace the local optical module with a new one to ensure they are of the same type.
  4. Add -5 dBm (recommended) attenuators to the optical module.
  5. If the problem persists after the preceding steps, collect alarms, logs, and configurations, and contact technical support personnel.