No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Alarm Handling

S600-E V200R010C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
RMON_1.3.6.1.4.1.2011.1.3.4.0.1 pririsingAlarm

RMON_1.3.6.1.4.1.2011.1.3.4.0.1 pririsingAlarm

Description

RMON/3/RISING:OID [OID] Private alarm table [alarm-line-index] monitors [description] with the sample type being [sample-type], and the sampled alarm value [alarm-value] is greater than or equal to [alarm-upper-limit].

The value of the alarm entity was higher than prialarmRisingThreshold.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.1.3.4.0.1 Minor communicationsAlarm(2)

Parameters

Name Meaning

OID

Indicates the MIB object ID of the alarm.

alarm-line-index

Indicates the index of the alarm entry.

description

Indicates the description of the alarm entry

sample-type

Indicates the type of the sampled alarm.

alarm-value

Indicates the alarm value.

alarm-upper-limit

Indicates the upper threshold of the alarm.

Impact on the System

None.

Possible Causes

Cause 1:

If the current sampled value was greater than or equal to this threshold, and the last sampled value was less than this threshold, the alarm was generated.

Cause 2:

When this alarm entry became valid, the first sampled value was greater than or equal to this threshold, and prialarmStartupAlarm was equal to risingAlarm and risingOrFallingAlarm, the alarm was generated.

Procedure

  • This alarm is triggered only when the upper alarm monitoring threshold configured using the rmon prialarm command is reached. It is a user-configured monitoring alarm and does not affect services. Therefore, no action is required.

Related Information

None.

Translation
Download
Updated: 2019-09-24

Document ID: EDOC1000141873

Views: 157108

Downloads: 15

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next