Alarm Handling

S600-E V200R010C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
FSP_1.3.6.1.4.1.2011.5.25.183.1.22.9 hwStackLogicStackPortLinkErr

FSP_1.3.6.1.4.1.2011.5.25.183.1.22.9 hwStackLogicStackPortLinkErr

Description

FSP/3/LOGPORT_ILLEGAL: OID [OID] Stack port [octet1] connects to [octet2], and there are port members of the same logic stack port ID.

The logical stack ports are connected in a wrong order. The switch requires that the member ports in logical stack port 1 be connected to the member ports in stack port 2.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.183.1.22.9 Minor communicationsAlarm(2)

Parameters

Name Meaning
OID Indicates the ID of the MIB object.
[octet1] Indicates the local interface name.
[octet2] Indicates the name of remote interface connected to the local interface.

Impact on the System

The stack cannot be set up or the link generating the alarm is unavailable.

Possible Causes

The logical stack ports are connected in a wrong order.

Procedure

  1. Run the display stack port command to check member ports of logical stack ports.
  2. Connect the member ports in the local logical stack port 1 to those in the remote logical stack port 2, and connect the member ports in the local logical stack port 2 to those in the remote logical stack port 1.

Related Information

None.