Alarm Handling

S600-E V200R010C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
FSP_1.3.6.1.4.1.2011.5.25.183.1.22.11 hwPhyStackPortIsDown

FSP_1.3.6.1.4.1.2011.5.25.183.1.22.11 hwPhyStackPortIsDown

Description

FSP/3/STACKPORTISDOWN: OID [OID] Stack port [octet] state is down.

A member port that has been added to a logical stack port becomes Down.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.183.1.22.11 Minor communicationsAlarm(2)

Parameters

Name Meaning
OID Indicates the ID of the MIB object.
[octet] Indicates the local interface name.

Impact on the System

None.

Possible Causes

The member port is not connected.

Procedure

  • Check whether this port has been connected using a cable.

    • If no, connect it using a cable. The alarm handling ends.
    • If so, rectify the fault according to An Ethernet Interface Is Physically Down.