Alarm Handling

S600-E V200R010C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
SYSMIB_1.3.6.1.4.1.2011.5.25.19.2.14 hwSysCfgFileErrorNotification

SYSMIB_1.3.6.1.4.1.2011.5.25.19.2.14 hwSysCfgFileErrorNotification

Description

SYSMIB/4/CFGFILE_FAIL:OID [oid] The configuration file is invalid. (HwSysCFGFileIndex=[HwSysCFGFileIndex], HwSysCFGFileName=[HwSysCFGFileName], HwSysCfgFileReason=[HwSysCfgFileReason])

Failed to load the configuration file.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.19.2.14 Warning other(1)

Parameters

Name Meaning

oid

Indicates the MIB object ID of the alarm.

HwSysCFGFileIndex

Index ID

HwSysCFGFileName

Name of the configuration file

HwSysCfgFileReason

Causes triggering the alarm

Impact on the System

Services will not be affected.

Possible Causes

Failed to load the configuration file.

Procedure

  1. Check whether the configuration file exists on the device.

    • If the configuration file does not exist, download a configuration file from the server.

    • If the configuration file exists, go to Step 2.

  2. Check whether the length of the configuration file name is valid.

    • Check whether the length of the file name with the full path name exceeds 48 English characters. If the length exceeds 48 English characters, run the rename command to rename the file.

    • If the length is valid, go to Step 3.

  3. Collect alarm information and configuration information, and then contact technical support personnel.
  4. End.