Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ACLE_1.3.6.1.4.1.2011.5.1.2.2.1.1.4.4 hwAclResTotalCountExceedTrap

ACLE_1.3.6.1.4.1.2011.5.1.2.2.1.1.4.4 hwAclResTotalCountExceedTrap

Description

ACLE/4/ACL_RULERESFULL_TRAP:OID [OID] The rule resource usage has reached [INTEGER]%.(Slot=[OCTET], Stage=[OCTET])

The ACL resource usage reached 100%.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.1.2.2.1.1.4.4 Warning qualityOfServiceAlarm(3)

Parameters

Name Meaning
OID Indicates the ID of the MIB object.
INTEGER Indicates the ACL resource usage. The value is fixed as 100.
Slot Indicates the stack ID of the card where the alarm is generated.
Stage Indicates the ACL processing stage when the alarm is generated.

Impact on the System

None

Possible Causes

The ACL resource usage reached 100%.

Procedure

  1. Run the display acl resource slot [ slot-id ] command in the system view to check whether the ACL resource usage on the switch is the same as the value in the alarm.

    • If so, go to step 2.
    • If not, go to step 3.

  2. The following are suggestions:

    • Check whether global or simplified traffic policy can be disabled on the device. If so, change the global or simplified traffic policy into interface-based traffic policy.
    • Replace the cards with those that provide more ACL resources.

    After the operation, check whether the alarm is cleared.

    • If so, no further action is required.
    • If not, go to step 3.

  3. Collect alarm, log, and configuration information, and contact technical support personnel.