Alarm Handling

S600-E V200R010C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
IFNET_1.3.6.1.6.3.1.1.5.3 linkDown

IFNET_1.3.6.1.6.3.1.1.5.3 linkDown

Description

IFNET/1/IF_LINKDOWN: OID [oid] Interface [interface-index] turned into DOWN state.(AdminStatus=[INTEGER],OperStatus=[INTEGER],InterfaceName=[OCTET])

The status of the link protocol on the interface became Down.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.6.3.1.1.5.3 Critical other(1)

Parameters

Name Meaning

oid

Indicates the MIB object ID of the alarm.

interface-index

Indicates the interface index.

AdminStatus

Indicates the admin status, which means whether the interface has been disabled.
  • 1: undo shutdown
  • 2: shutdown

OperStatus

Indicates the operating status, which means the link layer protocol status of the interface.
  • 1: Up
  • 2: Down

InterfaceName

Indicates the interface name.

Impact on the System

The interface cannot forward packets normally.

Possible Causes

Cause 1:

The interface became Down and the link was disconnected.

Cause 2:

The VLANIF interface is deleted.

Procedure

  1. If the VLANIF interface is deleted, this trap message is informational only. No action is required, go to Step 7.
  2. Run the display this command in the interface view to check whether interfaces on both ends are shut down.

    • If so, go to Step 3.

    • If not, go to Step 4.

  3. Run the undo shutdown command in the interface view to check whether the alarm is cleared.

    • If so, go to Step 7.

    • If not, go to Step 4.

  4. Check whether the cable and optical module are loosened or dropped.

    • If so, go to Step 6.

    • If not, go to Step 5.

  5. Connect the physical link correctly and then check whether the alarm is cleared.

    • If so, go to Step 7.

    • If not, go to Step 6.

  6. Collect alarm information and configuration information, and then contact technical support personnel.
  7. End.