Alarm Handling

S600-E V200R010C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
IFPDT_1.3.6.1.4.1.2011.5.25.219.2.12.3 hwPortNoSupportOETrap

IFPDT_1.3.6.1.4.1.2011.5.25.219.2.12.3 hwPortNoSupportOETrap

Description

IFPDT/4/NOSUPPORT_OEPORT:OID [oid] The 1000base-T optical/electrical module or optical module cannot be installed on the port when the port is used as a stack port. (EntityPhysicalIndex=[INTEGER], EntityIfIndex=[INTEGER], EntPhysicalName=[OCTET], hwEntityTrapFaultID=[INTEGER]).

A copper module or GE optical module cannot be used on a stack port.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.219.2.12.3 Warning environmentalAlarm(6)

Parameters

Name Meaning
oid Indicates the ID of a MIB object.

EntityPhysicalIndex

Indicates the index of the physical entity.

EntityIfIndex

Indicates the interface index.

EntPhysicalName

Indicates the entity name. The entity name varies according to the card type.

hwEntityTrapFaultID

Indicates the error code.

Impact on the System

The copper module or GE optical module cannot be used on a stack port.

Possible Causes

The port has been configured as a stack port and cannot have any copper module or GE optical module installed.

Procedure

  • Replace the copper module or GE optical module with a 10GE optical module that can be used on the stack port.
  • If the stack port is not required, delete the stack port configuration to restore the port to a common service port. Then the copper module or GE optical module can be used on the port.
  • If the problem persists, contact technical support personnel.