Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
SRM_1.3.6.1.4.1.2011.5.25.129.2.5.11 hwPortPhysicalEthHalfDuplexAlarm

SRM_1.3.6.1.4.1.2011.5.25.129.2.5.11 hwPortPhysicalEthHalfDuplexAlarm

Description

SRM/4/HALFDUPLEXALARM:

OID [OID] The port works in half duplex mode.(EntityPhysicalIndex=[INTEGER1], BaseTrapSeverity=[INTEGER2], BaseTrapProbableCause=[INTEGER3], BaseTrapEventType=[INTEGER4], EntPhysicalName=[OCTET1], RelativeResource="[OCTET2]")

This alarm was generated when the Ethernet interface worked in half-duplex mode.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.129.2.5.11 Warning equipmentAlarm(5)

Parameters

Name Meaning
[OID] OID of the MIB
[INTEGER1] Entity index
[INTEGER2] Severity code
[INTEGER3] Error code
[INTEGER4] Code of the event type
[OCTET1] Entity name
[OCTET2] Name of the affected component

Impact on the System

It may result in packet loss, low bandwidth usage, or even network interruption.

Possible Causes

1. The local interface or the peer interface was configured to work in half-duplex mode.

2. One of the connected interfaces worked in auto-negotiation mode whereas the other interface worked in non-automatic negotiation mode.

Procedure

  1. Check whether the interface is expected to work in half-duplex mode.

    (1) If so, go to Step 5.

    (2) If not, go to Step 2.

  2. In the interface view of the local interface and the peer interface, run the display this command to check whether the half-duplex mode is configured.

    (1) If so, run the duplex full command to forcibly configure the interface to work in full-duplex mode.

    (2) If not, go to Step 4.

  3. In the interface view of the local interface and the peer interface, run the display this command to check whether one interface works in auto-negotiation mode whereas the other interface works in non-automatic negotiation mode.

    (1) If so, run the negotiation auto command to configure the interface working in non-automatic negotiation mode to work in auto-negotiation mode.

    (2) If not, go to Step 4.

  4. Contact technical support personnel.
  5. End.

Related Information

None

Translation