No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Alarm Handling

S600-E V200R010C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ENTITYTRAP_1.3.6.1.4.1.2011.5.25.219.2.2.3 hwBoardFail 132127

ENTITYTRAP_1.3.6.1.4.1.2011.5.25.219.2.2.3 hwBoardFail 132127

Description

ENTITYTRAP/2/BOARDFAIL: OID [oid] Board become failure for some reason. (Index=[INTEGER], EntityPhysicalIndex=[INTEGER], PhysicalName="[OCTET]", EntityTrapEntType=[INTEGER], EntityTrapFaultID=[INTEGER], EntityTrapReasonDescr="[OCTET]")

Some functions on the board did not take effect.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.219.2.2.3 Major equipmentAlarm(5)

Parameters

Name Meaning
OID Indicates the ID of the MIB object.
Index Indicates the index.
EntityPhysicalIndex Indicates the physical index.
PhysicalName Indicates the entity name.
EntityTrapEntType Indicates the entity type.
EntityTrapFaultID Indicates the error code.
EntityTrapReasonDescr Indicates the description of the alarm cause.

Impact on the System

The board may be unavailable, some functions on it did not take effect, and services may be interrupted.

Possible Causes

The clock module on the board was faulty.

Procedure

  1. Restart the faulty board and then check whether the corresponding clear alarm is displayed.

    • If so, the alarm handling ends.
    • If not, go to step 2.

  2. Replace the faulty board in the slot.
Translation
Download
Updated: 2019-04-18

Document ID: EDOC1000141873

Views: 124581

Downloads: 14

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next