Alarm Handling

S600-E V200R010C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
IFPDT_1.3.6.1.4.1.2011.5.25.157.2.220 hwOutputRateChangeOverThresholdNotice

IFPDT_1.3.6.1.4.1.2011.5.25.157.2.220 hwOutputRateChangeOverThresholdNotice

Description

IFPDT/4/PORT_OUTRATECHG: OID [oid] The output rate change ratio exceeded the threshold.(IfIndex = [INTEGER], InterfaceName = [STRING], ThresholdPercent = [INTEGER], CurrentStatisticalPeriodRate = [COUNTER64], LastStatisticalPeriodRate = [COUNTER64]).

The sudden traffic volume change percentage in the outbound direction of interfaces exceeded the alarm threshold.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.157.2.220 Warning qualityOfServiceAlarm(3)

Parameters

Name Meaning

OID

Indicates the trap OID.

IfIndex

Indicates the interface index.

InterfaceName

Indicates the interface name.

ThresholdPercent

Indicates the detection threshold of sudden traffic volume changes.

CurrentStatisticalPeriodRate

Rate of bytes on the interface in the current traffic statistics collection interval.

LastStatisticalPeriodRate

Rate of bytes on the interface in the previous traffic statistics collection interval.rval.

Impact on the System

Packet loss may occur on interfaces.

Possible Causes

The sudden traffic volume change percentage in the outbound direction of interfaces exceeded the alarm threshold.

Procedure

  1. Run the display this interface command to view the Output bandwidth utilization field, and check whether the sudden traffic in the inbound direction of interfaces is normal.

    • If so, no action is required.
    • If not, check whether a loop exists on the link.

  2. Collect log information, and contact technical support personnel.