No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Alarm Handling

S600-E V200R010C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ARP_1.3.6.1.4.1.2011.5.25.123.2.5 hwEthernetARPThresholdResumeAlarm

ARP_1.3.6.1.4.1.2011.5.25.123.2.5 hwEthernetARPThresholdResumeAlarm

Description

ARP/4/ARP_THRESHOLDRESUME_TRAP:OID [OID] The number of ARP entries was restored to the threshold. (entPhysicalIndex=[INTEGER], Slot name=[OCTET], Threshold=[COUNTER], Number of dynamic ARP entries=[COUNTER], Number of static ARP entries=[COUNTER]).

The number of ARP entries falls below the upper threshold.

Attribute

Alarm ID Alarm Severity Alarm Type

1.3.6.1.4.1.2011.5.25.123.2.5

Warning

qualityOfServiceAlarm(3)

Parameters

Name Meaning

oid

Indicates the MIB object ID of the alarm.

entPhysicalIndex

Indicates the index of the physical entity.

Slot name

Indicates the device name.

Threshold

Indicates the alarm threshold, that is, 70 percent of the total number of ARP entries supported by the switch. The alarm threshold cannot be modified.

Number of dynamic ARP entries

Indicates the number of dynamic ARP entries.

Number of static ARP entries

Indicates the number of static ARP entries.

Impact on the System

None

Possible Causes

The number of ARP entries on the device fell below the upper threshold.

Procedure

  1. This alarm message is informational only, and no action is required.

Related Information

None

Translation
Download
Updated: 2019-08-21

Document ID: EDOC1000141873

Views: 149997

Downloads: 14