Configuration Guide - Basic Configuration

S7700 and S9700 V200R010C00

This document describes methods to use command line interface and to log in to the device, file operations, and system startup configurations.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Upgrading the System Software Using the BootLoad Menu

Upgrading the System Software Using the BootLoad Menu

Networking Requirements

As shown in Figure 11-1, a PC is connected to the console interface on a switch and allows users to log in to the switch using terminal emulation software. The network adapter on the PC is connected to the Ethernet interface (management interface) on the switch.

The system software on the switch is faulty, and you cannot log in. To address this issue, you need to use the Ethernet submenu under the BootLoad menu to upload system software and specify it as the next startup system software. In this way, the switch can load the system software and start an upgrade.

Figure 11-1  Networking diagram of connecting a PC to a switch
NOTE:

In this example, HyperTerminal is used as terminal emulation software. If other third-party terminal emulation software is used, see the corresponding software user guide or online help.

Configuration Roadmap

  1. Deploy an FTP server and upload the target system software to the FTP working directory. In this example, configure the PC as the FTP server.
  2. Restart the switch and access the BootLoad menu.
  3. Set FTP parameters on the switch so that the switch can communicate with the FTP server. Use FTP to upload the target system software to the flash memory on the switch.
  4. In the submenu for modifying the flash description, configure the uploaded system software as the next startup system software.

Procedure

  1. Configure the PC as the FTP server and copy the system software of the switch to the FTP working directory.

    # Configure the IP address, user name, password, and working directory for the FTP server.

    Run an FTP server program on the PC, for example, wftpd32. Choose Security > Users/rights.... In the dialog box that is displayed as shown in Figure 11-2, click New User.... In the dialog box that is displayed, set the user name to user and password to huawei. Set Home Directory: to D:\BootLoad. Click Done to close the dialog box. Set the IP address of the PC to 192.168.1.6 and mask to 255.255.255.0.

    Figure 11-2  Configuring the FTP server

    # Upload the system software, such as S7700V200R010C00.cc, to D:\BootLoad. The upload process is not mentioned here.

  2. Restart the switch. When the following information is displayed, press Ctrl+B and enter the password to access the BootLoad menu. The default BootLoad password is Admin@huawei.com.

    Press CTRL+B to enter BootLoad menu : 2
    
    Password:     //Enter the BootLoad password.
    
    

  3. Set FTP parameters on the switch for setting up an FTP connection with the PC.

    # In the BootLoad menu, select 2 to access the Ethernet submenu.

    2
            Ethernet Submenu
    
         1. Download file to Flash through ethernet interface
         2. Upload Configuration file to Ftp through ethernet interface
         3. Modify parameters
         4. Return
    
    Enter your choice(1-4): 
    # In the Ethernet submenu, select 3 and modify the network parameters and system software name on the Ethernet interface.
            Ethernet Submenu
    
         1. Download file to Flash through ethernet interface
         2. Upload Configuration file to Ftp through ethernet interface
         3. Modify parameters
         4. Return
    
    Enter your choice(1-4): 3
    Note: Two protocols for download, tftp & ftp.
          The file max-length for tftp is 32M.
          You can modify the flags following the menu.
          tftp--0x80, ftp--0x0.
    
    'Enter' = use current information
    current board ip:
    input new :192.168.1.2            //Configure an IP address for the management interface on the MPU.
    current netmask:
    input new : 255.255.255.0         //Configure an IP address subnet mask for the management interface on the MPU.
    current server ip:
    input new : 192.168.1.6           //Enter the server IP address.
    current file name:
    input new : S7700V200R010C00.CC         //Enter the name of the system software to be loaded.
    current user name:
    input new : user          //Enter the server user name.
    current user password:
    input new :                //Enter the server password.
    current flag:0x0
    input new :                //Set the transfer protocol type to FTP. Use the default value.
    NOTE:

    The default values of parameters on a newly delivered switch are left empty.

  4. After the parameters are set, select 1 in the Ethernet submenu to load the target system software to the flash memory.

            Ethernet Submenu
    
         1. Download file to Flash through ethernet interface
         2. Upload Configuration file to Ftp through ethernet interface
         3. Modify parameters
         4. Return
    
    Enter your choice(1-4): 1
    Use ftp to download file : S7700V200R010C00.CC , please wait for a moment.
    ................. 
    Download file successfully. 

  5. Exit the Ethernet submenu. In the BootLoad menu, select 3 to specify the loaded system software for the next startup.

    3
    'Enter' = use current information
    current startup file name:S7700V200R010C00B230.cc
    new startup file name:S7700V200R010C00.cc     //Enter the name of the downloaded system software.
    
    Saved-configuration file
    '.'=clear field; 'Enter'=use current configuration;
    new=change to other configuration file;
    current: vrpcfg.zip
    new    :               //No action is required. Press Enter
    
    Saved-patch file
    '.'=clear field; Enter=use current patch;
    new=change to other patch file;
    current:
    new    :             //No action is required. Press Enter.

  6. Exit the Modify Flash description submenu. In the BootLoad menu, select 1 to start the switch.

    1

  7. Check the configuration.

    # After the switch starts, run the display version command in the CLI to check whether the switch version is the target version.
    <HUAWEI> display version
    Huawei Versatile Routing Platform Software
    VRP (R) software, Version 5.150 (S7700 V200R010C00)
    Copyright (C) 2000-2013 HUAWEI TECH CO., LTD
    HUAWEI S7706 Terabit Routing Switch uptime is 0 week, 0 day, 0 hour, 11 minutes
    BKP 0 version information:
    1. PCB      Version  : VER.A
    2. Support  PoE      : No
    3. Board    Type     : ET1D2BAKL
    4. MPU Slot Quantity : 2
    5. LPU Slot Quantity : 8
    6. SFU Slot Quantity : 4
    
    MPU 9(Master) : uptime is 0 week, 0 day, 0 hour, 10 minutes
    Flash Memory Size    : 128     M bytes
    MPU version information :
    1. PCB      Version  : VER.A
    2. MAB      Version  : 0
    3. Board    Type     : ET1D2MPUA000
    4. CPLD0    Version  : 100
    5. BootROM  Version  : 100
    6. BootLoad Version  : 100
    
    LPU 4 : uptime is 0 week, 0 day, 0 hour, 9 minutes
    SDRAM Memory Size    : 1024    M bytes
    Flash Memory Size    : 64      M bytes
    LPU version information :
    1. PCB      Version  : VER.A
    2. MAB      Version  : 0
    3. Board    Type     : ET1D2G48SX1E
    4. CPLD0    Version  : 100
    5. BootROM  Version  : 100
    6. BootLoad Version  : 1
    Tcam version information :
    1. Tcam size         : 10      M bits
    
    LPU 5 : uptime is 0 week, 0 day, 0 hour, 7 minutes
    SDRAM Memory Size    : 512     M bytes
    Flash Memory Size    : 64      M bytes
    LPU version information :
    1. PCB      Version  : VER.A
    2. MAB      Version  : 0
    3. Board    Type     : ET1D2X48SEC0
    4. CPLD0    Version  : 100
    5. BootROM  Version  : 100
    6. BootLoad Version  : 100
    Tcam version information :
    1. Tcam size         : 9       M bits
    
    SFU 12 : uptime is 0 week, 0 day, 0 hour, 9 minutes
    SDRAM Memory Size    : 512     M bytes
    Flash Memory Size    : 64      M bytes
    SFU version information :
    1. PCB      Version  : VER.A
    2. MAB      Version  : 0
    3. Board    Type     : ET1D2SFUD000
    4. CPLD0    Version  : 100
    5. BootROM  Version  : 100
    6. BootLoad Version  : 100
    
    CMU 15(Master) : uptime is 0 week, 0 day, 0 hour, 9 minutes
    CMU version information :
    1. PCB      Version  : VER.B
    2. MAB      Version  : 0
    3. Board    Type     : EH1D200CMU00
    
    CMU 16(Slave) : uptime is 0 week, 0 day, 0 hour, 9 minutes
    CMU version information :
    1. PCB      Version  : VER.B
    2. MAB      Version  : 0
    3. Board    Type     : EH1D200CMU00 

    The preceding command output shows that the system software version is S7700 V200R010C00, indicating that the system software is successfully upgraded.