No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Configuration Guide - Basic Configuration

S7700 and S9700 V200R010C00

This document describes methods to use command line interface and to log in to the device, file operations, and system startup configurations.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Restarting the Device

Restarting the Device

Pre-configuration Tasks

To make sure the specified system software and files take effect, restart the device after system startup configuration is complete.

Before restarting the device, configure system startup files.

Context

Use either of the following methods to restart the device:
  • Restart the device immediately after configuration: The device restarts immediately after the reboot command is run. You can also press the RST button on the device to restart.
  • Restart the device at a scheduled time: The device can be restarted at a specified time later. When the configuration is complete, you can configure the device to restart at time when few services are running to minimize the impact of device restart on services.

The device records information about restart and card reset. Run the display reset-reason command to view the device restart and card reset information.

If the active control board is restarted by pressing the RST button, the information about the reset of the board is not recorded. The information about the reset of a board is recorded only when the active control board is running properly and the standby control board is restarted by pressing the RST button.

  • Do not restart the device unless necessary because device restart causes service interruption in a short time.

  • Save the current configuration so that it will take effect after the device restarts.

Procedure

  • Restart the device immediately.

    In the user view, run the reboot [ fast | save diagnostic-information ] command to restart the device.

    • The fast parameter indicates quick restart of the device. The system does not ask you whether to save the configuration file in fast startup.

    • The save diagnostic-information parameter indicates that the system will save the diagnostic information to root directory of the storage device before restarting.

  • Restart the device at a scheduled time.

    In the user view, run the schedule reboot { at time | delay interval [ force ] } command to restart the device at a scheduled time.

    • at time specifies the specific time to restart the device.
    • delay interval [ force ] specifies the waiting time before restarting the device.

      If the force parameter is not specified, the system compares the configuration file with the current configuration. If the current configuration is different from the configuration file, the system asks you whether to save the current configuration. After you complete the selection, the system prompts you to confirm the configured restart time. Enter Y or y to make the configured restart time take effect. If the force parameter is specified, the system does not display any message, and the restart time takes effect directly. The current configuration is not compared or saved.

Checking the Configuration

  • If a scheduled restart is configured, run the display schedule reboot command to check the device restart configuration.
Translation
Download
Updated: 2019-08-21

Document ID: EDOC1000141895

Views: 58453

Downloads: 215

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next