No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Configuration Guide - MPLS

S7700 and S9700 V200R010C00

This document describes MPLS configurations supported by the switch, including the principle and configuration procedures of static LSPs, MPLS LDP, MPLS TE, MPLS QoS, MPLS OAM, Seamless MPLS, and MPLS common features, and provides configuration examples.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Configuring Failed Link Timer

Configuring Failed Link Timer

Context

CSPF uses a locally-maintained traffic-engineering database (TEDB) to calculate the shortest path to the destination address. Then, the signaling protocol applies for and reserves resources for the path. In the case of a link on a network is faulty, if the routing protocol fails to notify CSPF of updating the TEDB in time, this may cause the path calculated by CSPF to contain the faulty link.

As a result, the control packets, such as RSVP Path messages, of a signaling protocol are discarded on the faulty link. Then, the signaling protocol returns an error message to the upstream node. Receiving the link error message on the upstream node triggers CSPF to recalculate a path. The path recalculated by CSPF and returned to the signaling protocol still contains the faulty link because the TEDB is not updated. The control packets of the signaling protocol are still discarded and the signaling protocol returns an error message to trigger CSPF to recalculate a path. The procedure repeats until the TEDB is updated.

To avoid the preceding situation, when the signaling protocol returns an error message to notify CSPF of a link failure, CSPF sets the status of the faulty link to INACTIVE and enables a failed link timer. Then, CSPF does not use the faulty link in path calculation until CSPF receives a TEDB update event or the failed link timer expires.

Before the failed link timer expires, if a TEDB update event is received, CSPF deletes the failed link timer.

Perform the following configurations on the ingress node of an MPLS TE tunnel.

Procedure

  1. Run:

    system-view

    The system view is displayed.

  2. Run:

    mpls

    The MPLS view is displayed.

  3. Run:

    mpls te cspf timer failed-link interval

    The failed link timer is configured.

    By default, the failed link timer is set to 10 seconds.

    The failed link timer is a local configuration. If the failed link timers of nodes are set to different values, a failed link that is in ACTIVE state on one node may be in INACTIVE state on other nodes.