Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Enabling BFD for RSVP

Enabling BFD for RSVP

Context

Enabling BFD for RSVP in the following manners:

Perform the following configurations on the two RSVP neighboring nodes with a Layer 2 device exists between them.

Procedure

  • Enable BFD for RSVP globally.
    1. Run:

      system-view

      The system view is displayed.

    2. Run:

      mpls

      The MPLS view is displayed.

    3. Run:

      mpls rsvp-te bfd all-interfaces enable

      BFD for RSVP is enabled globally.

      After this command is run in the MPLS view, BFD for RSVP is enabled on all RSVP interfaces except the interfaces with BFD for RSVP that are blocked.

    4. (Optional) Disable BFD for RSVP on the RSVP interfaces that does not need to be enabled with BFD for RSVP.

      1. Run:
        quit

        Return to the system view.

      2. Run:
        interface interface-type interface-number

        The view of the RSVP-TE-enabled interface is displayed.

      3. On an Ethernet interface, run:

        undo portswitch

        The interface is switched to Layer 3 mode.

        By default, an Ethernet interface works in Layer 2 mode.

      4. Run:
        mpls rsvp-te bfd block

        BFD for RSVP is disabled on the interface.

  • Enable BFD for RSVP on the RSVP interface.
    1. Run:

      system-view

      The system view is displayed.

    2. Run:

      interface interface-type interface-number

      The view of the RSVP-TE-enabled interface is displayed.

    3. Run:

      mpls rsvp-te bfd enable

      BFD for RSVP is enabled on the RSVP interface.