S7700 and S9700 V200R010C00

This document describes MPLS configurations supported by the switch, including the principle and configuration procedures of static LSPs, MPLS LDP, MPLS TE, MPLS QoS, MPLS OAM, Seamless MPLS, and MPLS common features, and provides configuration examples.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Configuring BFD with Specific Parameters on the Ingress Node

Configuring BFD with Specific Parameters on the Ingress Node

Context

BFD parameters on the ingress node include the local and remote discriminators, minimum intervals for sending and receiving BFD packets, and local BFD detection multiplier. The BFD parameters affect BFD session setup.

You can adjust the local detection time according to the network situation. On an unstable link, if a small detection time is used, a BFD session may flap. You can increase the detection time of the BFD session.

NOTE:

Actual interval for the local device to send BFD packets = MAX {locally configured interval for sending BFD packets, remotely configured interval for receiving BFD packets}

Actual interval for the local device to receive BFD packets = MAX {remotely configured interval for sending BFD packets, locally configured interval for receiving BFD packets}

Local detection time = Actual interval for receiving BFD packets x Remotely configured BFD detection multiplier

Perform the following steps on the ingress node of the static LSP.

Procedure

  1. Run:

    system-view

    The system view is displayed.

  2. Run:

    bfd

    This node is enabled with the global BFD function. The global BFD view is displayed.

    By default, global BFD is disabled.

  3. Run:

    quit

    Return to the system view.

  4. Run:

    bfd cfg-name bind static-lsp lsp-name

    The BFD session is bound to the static LSP.

  5. Set local and remote discriminators of a BFD session.

    • Run:

      discriminator local discr-value

      The local discriminator is configured.

    • Run:

      discriminator remote discr-value

      The remote discriminator is configured.

    NOTE:

    The local and remote discriminators of the two ends on a BFD session must be correctly associated. That is, the local discriminator of the local device and the remote discriminator of the remote device are the same, and the remote discriminator of the local device and the local discriminator of the remote device are the same. Otherwise, the BFD session cannot be correctly set up. In addition, the local and remote discriminators cannot be modified after being successfully configured.

  6. (Optional) Run:

    min-tx-interval interval

    The interval for sending BFD packets is set on the local device.

  7. (Optional) Run:

    min-rx-interval interval

    The interval for receiving BFD packets is set on the local device.

  8. (Optional) Run:

    detect-multiplier multiplier

    The local BFD detection multiplier is set.

    By default, the value is 3.

  9. Run:

    process-pst

    The changes of the BFD session status can be advertised to the upper-layer application.

    By default, a static BFD session cannot report faults of the monitored service module to the system.

  10. Run:

    commit

    The configuration is committed.