Configuration Guide - MPLS

S7700 and S9700 V200R010C00

This document describes MPLS configurations supported by the switch, including the principle and configuration procedures of static LSPs, MPLS LDP, MPLS TE, MPLS QoS, MPLS OAM, Seamless MPLS, and MPLS common features, and provides configuration examples.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Checking the Connectivity of the TE Tunnel

Checking the Connectivity of the TE Tunnel

Procedure

  • Run the ping lsp [ -a source-ip | -c count | -exp exp-value | -h ttl-value | -m interval | -r reply-mode | -s packet-size | -t time-out | -v ] * te tunnel interface-number [ hot-standby | primary ] [ draft6 ] command to check the connectivity of the TE tunnel between the ingress and egress.

    If draft6 is specified, the ping lsp command is implemented according to draft-ietf-mpls-lsp-ping-06. By default, the command is implemented according to RFC 4379. If the hot-standby parameter is specified, the hot-standby CR-LSP can be tested.

  • Run the tracert lsp [ -a source-ip | -exp exp-value | -h ttl-value | -r reply-mode | -t time-out ] * te tunnel interface-number [ hot-standby | primary ] [ draft6 ] command to trace the hops of a TE tunnel.

    If draft6 is specified, the tracert lsp command is implemented according to draft-ietf-mpls-lsp-ping-06. By default, the command is implemented according to RFC 4379. If the hot-standby parameter is specified, the hot-standby CR-LSP can be tested.