PM/3/IDX_REACH_UPPER
PM/3/IDX_REACH_UPPER
Message
PM/3/IDX_REACH_UPPER: The number of measure has reached the upper limit ([max-number]).
Description
The number of items to be measured has reached the upper limit.
Parameters
Parameter Name
Parameter Meaning
[max-number]
The maximum number of items to be measured.
Possible Causes
The number of items to be measured has reached the upper limit.
Procedure
Run the display this command in the PM view to check current statistical tasks and bound instances.
Perform the following operations to reduce registered statistics indicators:
Run the undo statistics-tasktask-name command in the PM view to delete unnecessary statistical tasks.
Run the undo binding instance-typeinstance-type { all | instance { instance-name }& <1-5> } command to delete unwanted performance instances bound to a specified statistical task.