No relevant resource is found in the selected language.
Your browser version is too early. Some functions of the website may be unavailable. To obtain better user experience, upgrade the browser to the latest version.
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document.
Note: Even the most advanced machine translation cannot match the quality of professional translators.
Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
CLOCK/4/TOD_LOS
CLOCK/4/TOD_LOS
Message
CLOCK/4/TOD_LOS:The BITS[ULONG] 1pps-tod signal is loss.
Description
The 1pps-tod signal from the BITS input interface is lost.
Parameters
Parameter Name
Parameter Meaning
[ULONG]
Indicates the number of the BITS interface:
0: BITS0 input interface
1: BITS1 input interface
Possible Causes
1. The device where the BITS interface resides is faulty.
2. The cable connection between the BITS interface and the local device is abnormal.
Procedure
Run the display clock { bits0 | bits1 } command to check whether the BITS interface is working normally.
Check whether the cable connection is normal.
Check whether the BITS interface sends 1pps-tod signal.
If the preceding information is correct, Collect log information and configuration
information, and then contact technical support personnel.You can collect diagnostic information
using the display diagnostic-information command.