ALML/4/ENTRESETFAIL
ALML/4/ENTRESETFAIL
Message
ALML/4/ENTRESETFAIL:[STRING1] is reset unsuccessfully, The reset reason is: [STRING2].
Description
A board is abnormal and does not reset.
Parameters
Parameter Name
Parameter Meaning
[STRING1]
Information about the entity that fails to be reset, including the board name, board type, and board slot ID.
[STRING2]
Reason for reset failure of an entity.
Possible Causes
The board is reset abnormally and is not manually reset.
Procedure
Manually reset the board to determine whether it can register normally.
If so, the alarm handling ends.
If not, go to step 2.
Collect log information and configuration
information, and then contact technical support personnel.You can collect diagnostic information
using the display diagnostic-information command.