MAD/4/CONFLICT_DETECT
MAD/4/CONFLICT_DETECT
Message
MAD/4/CONFLICT_DETECT:Multi-active scenario is
detected.
Description
A multi-active scenario was detected.
Parameters
Parameter Name
Parameter Meaning
None
None
Possible Causes
The CSS link
was faulty.
Procedure
Run the display css port command to view the CSS port status.
If the CSS port status is up, go to step 3.
If the CSS port status is down, go to step 2.
Check the reason why the CSS port went physically Down.
For details, see "An Ethernet Interface Is Physically Down" in the S7700 and S9700V200R010C00 Troubleshooting
- Interface Faults.
The CSS port of this device became faulty or a software
error occurred on the device. You need to collect log information and configuration
information, and then contact technical support personnel.You can collect diagnostic information
using the display diagnostic-information command.