MCAST/3/ACL
MCAST/3/ACL
Message
MCAST/3/ACL:Failed to Down ACL to LPU. (ACLID=[ULONG]
, SlotID=[ULONG], Result=[ULONG])
Description
Delivering the ACL to an interface board fails due
to an RPC communication error.
Parameters
Parameter Name
Parameter Meaning
ACLID
ACL rule name
SlotID
ID of slot where an interface board is inserted
Result
Indicates the error code of an ACL delivery failure.
The error code 0 means that the ACL has been successfully delivered.
Possible Causes
An error occurs in the communication through the RPC
on an interface board.
Procedure
Run the display device command to check
the status of the interface board when the event happens.
If the interface board is restarting, this log is normal
and does not need to be processed.
If the interface board is in the running status, check
whether the Ecm status of the interface board is normal. If not normal,
collect log information and configuration information, and then contact
technical support personnel. For details, see Troubleshooting-Information Collection-Collecting Diagnostic Information.