Configuration Guide - Interface Management

S1720, S2700, S5700, and S6720 V200R010C00

This document describes the principles and configurations of interfaces and provides configuration examples.

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
How Can Packet Loss Be Avoided When Two Interfaces at Both Ends of a Link Work in Auto-Negotiation Mode and Use the Half-Duplex Mode?

How Can Packet Loss Be Avoided When Two Interfaces at Both Ends of a Link Work in Auto-Negotiation Mode and Use the Half-Duplex Mode?

You can configure the local and remote devices to work in non-auto-negotiation mode, and set their duplex mode to full-duplex to avoid packet loss.

The configuration is as follows:
<HUAWEI> system-view
[HUAWEI] interface gigabitethernet 0/0/1
[HUAWEI-GigabitEthernet0/0/1] undo negotiation auto
[HUAWEI-GigabitEthernet0/0/1] duplex full