Configuration Guide - Reliability

S1720, S2700, S5700, and S6720 V200R010C00

This document describes the configuration of BFD, DLDP, VRRP, SmartLink, CFM, EFM, Y.1731 and MAC swap loopback to ensure reliability on the device.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Configuring Association Between CFM and EFM

Configuring Association Between CFM and EFM

Context

For details on the principle and usage scenarios of association between EFM and CFM, see Fault Information Advertisement Between CFM and Other Modules.

Association between EFM and CFM is bidirectional. When EFM detects a link fault, it will notify CFM of the fault. When CFM detects a link fault, it will notify EFM of the fault.

Pre-configuration Tasks

Before configuring association between EFM and CFM, complete the following tasks:
NOTE:

Only the S2720EI, S5720LI, S5720S-LI, S5720SI, S5720S-SI, S5720EI, S5720HI, S6720EI, and S6720S-EI support this function.

Procedure

  1. Run:

    system-view

    The system view is displayed.

  2. Run:

    oam-mgr

    The OAM management view is displayed.

  3. Run the following commands as required.

    • Unidirectional association

      Run:

      oam-bind ingress efm interface interface-type interface-number egress cfm md md-name ma ma-name

      EFM is configured to report faults to CFM.

      Run:

      oam-bind ingress cfm md md-name ma ma-name egress efm interface interface-type interface-number

      CFM is configured to report faults to EFM.

    • Bidirectional association

      Run:

      oam-bind cfm md md-name ma ma-name efm interface interface-type interface-number

      EFM and CFM are configured to report faults to each other.

    NOTE:

    The functions of two commands used to configure association functions in opposite directions are the same as those of the command used to configure the bidirectional association function.

    If the oam-bind cfm md md-name ma ma-name efm interface interface-type interface-number command is run, oam-bind ingress efm interface interface-type interface-number egress cfm md md-name ma ma-name and oam-bind ingress cfm md md-name ma ma-name egress efm interface interface-type interface-number will be displayed in the configuration file.

    After EFM is associated with other functional modules, pay attention to the following points: If EFM is disabled on an interface, association between EFM and other functional modules is deleted. If an MA or MD is deleted, the association between Ethernet CFM and other functional modules is deleted.