Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Manually Switching Data Flows to the Other Link

Manually Switching Data Flows to the Other Link

Context

When both the primary and backup links are working normally, you can manually switch data flows from the active link to the standby link or from the standby link to the active link.

Ensure the following conditions are met before performing a link switchover:

  • Both the master and slave interfaces exist and are in Up state.
  • The smart-link { lock | force } command has not been configured to lock data flows to the master or slave interface.

The smart-link manual switch command can be executed repeatedly in the Smart Link group view. Each time you run the command, a link switchover is performed, causing millisecond-level packet loss.

Procedure

  1. Run:

    system-view

    The system view is displayed.

  2. Run:

    smart-link group group-id

    The Smart Link group view is displayed.

  3. Run:

    smart-link manual switch

    Data flows are switched to the other interface.