Configuration Guide - VPN

S1720, S2700, S5700, and S6720 V200R010C00

This document describes the VPN configuration procedures and provides configuration examples.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Configuring the Multi-Homed Preference for a VSI

Configuring the Multi-Homed Preference for a VSI

Context

If the VSIs of two PEs to which a CE is dual homed are Up, the PE with the higher priority functions as the master PE, whereas the PE with the lower priority functions as the backup PE. Therefore, you should not assign the same priority to the PEs, because this hinders the master/backup PE negotiation.

Do as follows on the PEs:

Procedure

  1. Run:

    system-view

    The system view is displayed.

  2. Run:

    vsi vsi-name

    The VSI view is displayed.

  3. Run:

    multi-homing-preference preference-value

    The multi-homed preference is configured for a VSI.

    When the VSIs of the two PEs that a CE accesses are Up, the PE with the higher preference serves as the active PE, and the PE with the lower preference works as the standby PE. The active PE is responsible for forwarding the traffic of the CE; the standby PE is only responsible for checking whether the VSI of the active PE is Up. After a PE is selected as the standby PE, the status of the VSI of the standby PE is set to Down. After the VSI of the active PE becomes Down, the standby PE becomes the new active PE.

    After the BGP session between the two PEs that a CE accesses becomes Down, the PW of the PE with the lower preference becomes Up, and the PW between the two PEs becomes Up.