Alarm Handling

S9300, S9300E, and S9300X V200R010C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
EOAM_Y1731_1.3.6.1.4.1.2011.5.25.136.1.6.48 hwY1731AisExceedMaxPktNum

EOAM_Y1731_1.3.6.1.4.1.2011.5.25.136.1.6.48 hwY1731AisExceedMaxPktNum

Description

EOAM_Y1731/4/AISEXCEEDPKTNUM:OID [OID] The number of AIS packets transmitted in one second exceeds the maximum.(Maximum=[INTEGER])

The number of AIS packets sent and received within 1s exceeded the alarm threshold.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.136.1.6.48 warning qualityOfServiceAlarm (3)

Parameters

Name Meaning

oid

Indicates the MIB object ID of the alarm.

Maximum

Maximum number of sent and received AIS packets.

Impact on the System

Subsequent AIS packets will not be processed and therefore AIS sending/receiving fails.

Possible Causes

The number of AIS packets sent and received within 1s exceeded the alarm threshold.

Procedure

  1. Run the display cfm md md-name command to view the MD and MA names of a device.
  2. Perform the following sub-steps:

    1. Run the cfm md md-name command to enter an MD view.

    2. Run the ma ma-name command to enter the MA view of the MD.

    3. Run the undo ais vlan command to delete AIS VLAN configuration. Then check whether the trap is cleared. If the trap persists, go to step 3.

  3. Repeat step 2 to delete AIS VLAN configurations. Then check whether the trap is cleared. If the trap persists, go to step 4.
  4. Collect alarm information and configuration information, and then contact technical support personnel.
  5. End.