Alarm Handling

S9300, S9300E, and S9300X V200R010C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
BASETRAP_1.3.6.1.4.1.2011.5.25.129.2.5.11 hwPortPhysicalEthHalfDuplexAlarm

BASETRAP_1.3.6.1.4.1.2011.5.25.129.2.5.11 hwPortPhysicalEthHalfDuplexAlarm

Description

BASETRAP/4/HALFDUPLEXALARM: OID [oid] The port works in half duplex mode. (EntityPhysicalIndex=[INTEGER], BaseTrapSeverity=[INTEGER], BaseTrapProbableCause=[INTEGER], BaseTrapEventType=[INTEGER], EntPhysicalName="[OCTET]", RelativeResource="[OCTET]")

The operation mode of the interface is negotiated to half duplex after certain events occur, for example, the interface status becomes Up or Down, or the user manually sets the operation mode to half duplex.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.129.2.5.11 Warning qualityOfServiceAlarm(3)

Parameters

Name Meaning
[oid] Indicates the ID of the MIB object.
EntityPhysicalIndex Indicates the entity index.
HwBaseTrapSeverity Indicates the severity level of the alarm.
HwBaseTrapProbableCause Indicates the possible cause of the alarm.
HwBaseTrapEventType Indicates the alarm type:
  • communicationsAlarm (2): alarm for communication problems
  • qualityOfServiceAlarm (3): alarm for service quality
  • processingErrorAlarm (4): alarm for processing errors
  • equipmentAlarm (5): alarm for the equipment
  • environmentalAlarm (6): alarm for the environment

The type of this alarm is qualityOfServiceAlarm (3).

EntPhysicalName Indicates the entity name.
RelativeResource Indicates the resource related to this alarm.

Impact on the System

The interface alternates between Up and Down states.

Possible Causes

The operation mode of the interface is negotiated to half duplex after certain events occur, for example, the interface status becomes Up or Down, or the user manually sets the operation mode to half duplex.

Procedure

  1. Check whether the duplex half or auto duplex half command has been executed to set the operation mode to half duplex.

    • If so, the alarm handling ends.
    • If not, go to step 2.

  2. Run the shutdown and undo shutdown commands on this interface and then check whether the interface works in full duplex mode.

    • If so, the alarm handling ends.
    • If not, collect alarm information and configuration information, and then contact technical support personnel.

Related Information

None

Translation
Download
Updated: 2019-08-21

Document ID: EDOC1000142054

Views: 192420

Downloads: 44

Average rating:
This Document Applies to these Products
Related Version
Related Documents
Share