No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Alarm Handling

S9300, S9300E, and S9300X V200R010C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
SNMP_1.3.6.1.6.3.1.1.5.5 authenticationFailure

SNMP_1.3.6.1.6.3.1.1.5.5 authenticationFailure

Description

SNMP/4/AUTHFAIL:OID [oid] authenticationFailure. (RemoteIpAddressType=[INTEGER], RemoteIpAddress=[STRING])

The authentication of SNMP failed.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.6.3.1.1.5.5

Warning

other(1)

Parameters

Name Meaning

oid

Indicates the MIB object ID of the alarm.

RemoteIpAddressType

Indicates the IP address type of the remote peer

RemoteIpAddress

Indicates the IP address of the remote peer

Impact on the System

The system will not be affected.

Possible Causes

  • The incorrect community name was used to connect devices.

  • The incorrect user name of SNMPv3 was used to connect devices.

Procedure

  1. Run the display current-configuration | include snmp-agent command in the user view to check whether community or SNMPv3 user name configurations are correct.

    • If so, go to Step 3.

    • If not, go to Step 2.

  2. To modify the community, run the snmp-agent community command in the system view. To create a correct user, run the snmp-agent usm-user command in the system view. Then, check whether the alarm is cleared.

    • If so, go to Step 4.
    • If not, go to Step 3.

  3. Collect alarm information and configuration information, and then contact technical support personnel.
  4. End.

Related Information

None.