Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ENTITYEXTTRAP_1.3.6.1.4.1.2011.5.25.31.2.2.9 hwEntityHigStateChangeNotify

ENTITYEXTTRAP_1.3.6.1.4.1.2011.5.25.31.2.2.9 hwEntityHigStateChangeNotify

Description

ENTITYEXTTRAP/2/HGSTATECHANGE:OID [oid] Higig port state has changed. (SlotID=[STRING], UnitID=[INTEGER], PortID=[STRING], PeerSlotID=[STRING], ChangedTimes=[STRING])

The HG channel state has changed.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.31.2.2.9 Major communicationsAlarm(2)

Parameters

Name Meaning
OID Indicates the ID of a MIB object.
SlotID Indicates the slot ID.
UnitID Indicates the chip ID.
PortID Indicates the port number of the HG channel.
PeerSlotID Indicates the slot ID of the remote card.
ChangedTimes Indicates the number of times the HG channel state has changed.

Impact on the System

The HG channel cannot forward packets normally. During inter-card traffic forwarding, packets are lost or cannot be forwarded.

Possible Causes

  • The local or remote card is not securely installed.
  • The local or remote card connector is faulty.
  • The local or remote card is faulty.

Procedure

  1. Run the display device command to check whether the cards have registered normally. If the local and remote cards have registered normally, the cards have been securely installed. Otherwise, remove and reinstall the cards and then check whether this alarm persists.
  2. Remove the local and remote cards and then check whether there are bent pins. If pins of one card are bent or damaged, this card is damaged.
  3. Replace the card.