Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
BASETRAP_1.3.6.1.4.1.2011.5.25.129.2.4.2 hwCPUUtilizationResume

BASETRAP_1.3.6.1.4.1.2011.5.25.129.2.4.2 hwCPUUtilizationResume

Description

BASETRAP/4/CPUUSAGERESUME: OID [oid] CPU utilization recovered to the normal range. (Index=[INTEGER], BaseUsagePhyIndex=[INTEGER], UsageType=[INTEGER], UsageIndex=[INTEGER], Severity=[INTEGER], ProbableCause=[INTEGER], EventType=[INTEGER],PhysicalName="[OCTET]", RelativeResource="[OCTET]", UsageValue=[INTEGER], UsageUnit=[INTEGER], UsageThreshold=[INTEGER])

This recovery notification is generated when the CPU usage is reduced to the normal range.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.129.2.4.2 Warning processingErrorAlarm(4)

Parameters

Name Meaning
[oid] Indicates the ID of the MIB object.
Index Indicates the index of the entity. The entity in an alarm on the CPU is a board.
BaseUsagePhyIndex Indicates the index of the physical entity. The entity in an alarm on the CPU is a board.
UsageType Indicates the type of the alarm on usage.
UsageIndex Indicates the index of the sub-entity of the alarm entity. In the alarm on CPU usage, the fixed value of this parameter is 0.
ProbableCause Indicates the possible causes of the alarm. The codes of the possible causes are as follows:

1024: IANAITUPROBABLECAUSE_OTHER indicates that the causes are unknown.

EventType Indicates the alarm type. Alarms are classified into the following types:
  • communicationsAlarm (2)
  • qualityOfServiceAlarm (3)
  • processingErrorAlarm (4)
  • equipmentAlarm (5)
  • environmentalAlarm (6)

This alarm is an alarm of the environmentalAlarm type.

PhysicalName Indicates the name of the entity. In the alarm message, this parameter indicates a board.
RelativeResource Indicates the resources that are associated with the alarm. The current value on the device is null.
UsageValue Indicates the CPU usage of the current board.
UsageUnit Indicates the unit of the CPU usage. The unit is percent.
UsageThreshold Indicates the alarm threshold of CPU usage.

Impact on the System

None.

Possible Causes

The CPU usage is reduced to the normal range.

Procedure

  1. This is a normal notification and no action is required.