Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
IFPDT_1.3.6.1.4.1.2011.5.25.157.2.247 hwBoardNotSupportAssignTrunk

IFPDT_1.3.6.1.4.1.2011.5.25.157.2.247 hwBoardNotSupportAssignTrunk

Description

IFPDT/4/TRUNKMEMSPEC: OID [OID] This card does not support extensions of Eth-Trunk specifications. The number of Eth-Trunk members on this card is 8. (PhysicalIndex=[INTEGER], PhysicalName=[OCTET])

The card on the device does not support Eth-Trunk specification extensions.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.157.2.247 Warning equipmentAlarm(5)

Parameters

Name Meaning

OID

Indicates the trap OID.

PhysicalIndex

Indicates the index of the card.

PhysicalName

Indicates the name of the card.

Impact on the System

Load balancing of the Eth-Trunk may be uneven, and packets may be lost when traffic is heavy.

Possible Causes

The device was configured with Eth-Trunk specification extensions, but a running card on the device does not support Eth-Trunk specification extensions.

Procedure

  1. Run the display trunk configuration command to check whether the configured number of trunk-member is greater than 8.

    • If the configured number of trunk-member is greater than 8, go to step 2.

    • If the configured number of trunk-member is not greater than 8, go to step 4.

  2. Check the card in the alarm and check whether the card supports Eth-Trunk specification extensions.

    • If the card does not support Eth-Trunk specification extensions, go to step 3.

    • If the card supports Eth-Trunk specification extensions, go to step 4.

    NOTE:

    Cards are classified into cards with and without Eth-Trunk specification extension. Cards with Eth-Trunk specification extension are as follows:

    • S9300 and S9300X: FC series, SC series, EE series, X series, LE1D2S04SEC0, LE1D2X32SEC0, and LE1D2H02QEC0 cards

    • S9300E: FC series, SC series, EE series, X series, LE1D2S04SEC0, LE1D2X32SEC0, LE1D2H02QEC0, and LE2D2X48SEC0 cards

  3. Run the display trunk resource command to check whether the configured number of Eth-Trunk member interfaces is greater than 8.

    • If the configured number of Eth-Trunk member interfaces is greater than 8, go to step 4.

    • If the configured number of Eth-Trunk member interfaces is not greater than 8 and the subsequently configured number of Eth-Trunk member interfaces is not greater than 8, no action is required.

  4. Contact technical support personnel.