Alarm Handling

S9300, S9300E, and S9300X V200R010C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
PIM_1.3.6.1.4.1.2011.5.25.149.4.0.15 hwPimStarGExceed

PIM_1.3.6.1.4.1.2011.5.25.149.4.0.15 hwPimStarGExceed

Description

PIM/3/hwPimStarGExceed:OID [oid] PIM (*, G) entries of all instances cannot be created because the limit is reached. (hwPimNotificationAddressType=[integer], hwPimNotificationSrcAddr=[binary], hwPimNotificationGrpAddr=[binary], hwPimStarGTotalCount=[integer], hwPimInstanceName=[string])

The number of global PIM (*, G) entries created exceeded the maximum number of global PIM (*, G) entries allowed.

Attribute

Alarm ID Alarm Severity Alarm Type

1.3.6.1.4.1.2011.5.25.149.4.0.15

Minor

communicationsAlarm

Parameters

Name Meaning

oid

Indicates the MIB object ID of the alarm.

hwPimNotificationAddressType

Group address type:
  • 1: IPv4 address

  • 2: IPv6 address

hwPimNotificationSrcAddr

Source address

hwPimNotificationGrpAddr

Group address

hwPimStarGTotalCount

Maximum number of global PIM (*, G) entries allowed

hwPimInstanceName

Name of the VPN instance that caused the global PIM (*, G) entries to exceed the maximum number of global PIM (*, G) entries allowed

Impact on the System

No more PIM (*, G) entries can be created.

Possible Causes

The number of global PIM (*, G) entries created exceeded the maximum number of global PIM (*, G) entries allowed.

Procedure

  1. Confirm whether network expansion is required. If network expansion is required, contact technical support personnel.
  2. If the global PIM (*, G) entries of an address family indicated in the alarm information are not needed, delete them to reduce the number of global PIM (*, G) entries.
  3. End.