Alarm Handling

S9300, S9300E, and S9300X V200R010C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ENTITYTRAP_1.3.6.1.4.1.2011.5.25.219.2.3.5 hwCardInvalid 135470

ENTITYTRAP_1.3.6.1.4.1.2011.5.25.219.2.3.5 hwCardInvalid 135470

Description

ENTITYTRAP/1/CARDINVALID:OID [oid] Card is invalid for some reason. (Index=[INTEGER], EntityPhysicalIndex=[INTEGER], PhysicalName="[OCTET]", EntityTrapEntType=[INTEGER], EntityTrapFaultID=[INTEGER], EntityTrapReasonDescr="[OCTET]")

Subcard states on the two MPUs are different.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.219.2.3.5 Critical environmentalAlarm(6)

Parameters

Name Meaning
oid Indicates the ID of a MIB object.
Index Indicates an alarm ID.
EntityPhysicalIndex Indicates the index of the physical entity where the alarm is reported.
PhysicalName Indicates the physical entity name.
EntityTrapEntType Indicates the alarm type.
EntityTrapFaultID Indicates the error code of the alarm.
EntityTrapReasonDescr Indicates the cause of the alarm.

Impact on the System

The standby MPU does not work, which may affect services in the switch.

Possible Causes

The active or standby MPU has a subcard installed, but the other MPU does not. This type of MPUs used in the cluster detects states of CSS subcards before registration. In the cluster member switch, the active or standby MPU has a CSS subcard installed, but the other MPU does not. Therefore, this alarm is generated.

Procedure

  • Ensure the same subcard state on the two MPUs. For example, install a subcard in the MPU with a vacant subcard slot.

Related Information

None