Alarm Handling

S9300, S9300E, and S9300X V200R010C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
RSVP_1.3.6.1.4.1.2011.5.25.148.1.12.2.1 hwRsvpTeHelloLost

RSVP_1.3.6.1.4.1.2011.5.25.148.1.12.2.1 hwRsvpTeHelloLost

Description

RSVP/2/HWRSVPHELLOLOST:OID [oid] The RSVP Hello neighbor is lost. (IpAddress=[ipaddr])

The RSVP neighbor relationship was interrupted.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.148.1.12.2.1 Major communicationsAlarm(2)

Parameters

Name Meaning

oid

Indicates the MIB object ID of the alarm.

IpAddress

IP address of a neighbor

Impact on the System

If GR has been enabled, services will not be affected. If GR has not been enabled, the LSP goes Down or a master/slave LSP switchover is performed using FRR.

Possible Causes

The RSVP neighbor or the link over which the RSVP neighbor relationship is established became faulty.

Procedure

  1. Check whether the physical link or the RSVP neighbor is faulty.

    • If so, repair the physical link or restart the RSVP neighbor.

    • If not, go to step 2.

  2. Run the display ip routing-table command to check whether there is a route to the RSVP neighbor.

    • If so, go to step 3.

    • If not, configure an IGP to advertise routes.

  3. Collect alarm information and configuration information, and then contact technical support personnel.
  4. End.

Related Information