Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
OSPFV3_1.3.6.1.4.1.2011.5.25.147.0.13 hwOspfv3LastAuthKeyExpiry

OSPFV3_1.3.6.1.4.1.2011.5.25.147.0.13 hwOspfv3LastAuthKeyExpiry

Description

OSPFV3/2/LASTAUTHKEYEXPIRY:OID [oid] The last authentication key in keychain has expired. (RouterId=[gauge], IfName=[octet])

The last active key ID in the keychain expired.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.147.0.13 Major processingErrorAlarm(4)

Parameters

Name Meaning

oid

Indicates the MIB object ID of the alarm.

RouterId

Local router ID with its value as a decimal integer

IfName

Interface name

Impact on the System

The system may be attacked by invalid packets.

Possible Causes

The last active key ID in the keychain expired.

Procedure

  1. Run the display keychain keychain-name [ key-id key-id ] command to check the keychain configuration.

    • If the last active key ID in the keychain expired, go to Step 2.
    • If there are still active key IDs in the keychain, go to Step 3.

  2. Check the Timer Mode field in the keychain configuration.

    • If the value of the Timer Mode field is Periodic, the system automatically prolongs the active period of the key ID.
    • If the value of the Timer Mode field is Absolute, you need to run the keychain command to configure a new keychain.

  3. Collect alarm information and configuration information, and then contact technical support personnel.