Alarm Handling

S9300, S9300E, and S9300X V200R010C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
IFPDT_1.3.6.1.4.1.2011.5.25.157.2.211 hwNotSameBoardInTrunk

IFPDT_1.3.6.1.4.1.2011.5.25.157.2.211 hwNotSameBoardInTrunk

Description

IFPDT/4/NOTSAMEBOARDINTRUNK:OID [oid] The Eth-Trunk contains member ports on different types of cards, Load balancing of the Eth-Trunk may be abnormal. (EntityIfIndex=[INTEGER], EntPhysicalName=[OCTET]).

Load balancing may be abnormal when interfaces on different types of cards join the same Eth-Trunk.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.157.2.211 Warning environmentalAlarm(6)

Parameters

Name Meaning
oid Indicates the ID of a MIB object.
INTEGER Indicates the entity index.
OCTET Indicates the entity name.

Impact on the System

Traffic is unevenly load balanced among Eth-Trunk member interfaces. As a result, excess packets or packet loss may occur on non-known unicast traffic.

Possible Causes

During configuration restoration, interfaces on different types of cards joined the same Eth-Trunk. For example, interfaces on EC and non-EC series cards joined the same Eth-Trunk. See assign trunk.

Procedure

  1. Remove all interfaces of a card from the Eth-Trunk and ensure that member interfaces of the Eth-Trunk are on cards of the same type. If the alarm is not cleared, contact technical support personnel.