No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Alarm Handling

S9300, S9300E, and S9300X V200R010C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
L2V_1.3.6.1.4.1.2011.5.25.119.4.1.2.5 hwPWVcDeleted

L2V_1.3.6.1.4.1.2011.5.25.119.4.1.2.5 hwPWVcDeleted

Description

L2V/4/PWE3VC_DEL_T:OID [oid] The PWE3 VC has been deleted. (VcId=[GAUGE], VcType=[INTEGER], PeerAddress=[IPADDR], InterfaceIndex=[INTEGER], VcInboundLabel=[GAUGE], VcOutboundLabel=[GAUGE], SecondaryPw=[INTEGER], InterfaceName=[STRING], SwitchVcId=[GAUGE])

The LDP VC was deleted.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.119.4.1.2.5

Warning

qualityOfServiceAlarm (3)

Parameters

Name Meaning

oid

Indicates the MIB object ID of the alarm.

VcId

ID of the VC

VcType

Type of the VC. The values are as follows:
  • 0: initial value
  • 1: FR
  • 2: ATM AAL5
  • 3: ATM cell relay
  • 4: VLAN
  • 5: Ethernet
  • 6: HDLC
  • 7: PPP
  • 9: ATM cell VCC
  • 10: ATM cell VPC
  • 11: IP-layer 2 (used for heterogeneous IP-interworking between Huawei devices and non-Huawei devices)
  • 12: ATM, 1-to-1 VCC cell mode
  • 13: ATM, 1-to-1 VPC cell mode
  • 14: ATM, AAL5 PDU VCC transport
  • 64: heterogeneous interworking

PeerAddress

IP address of the peer

InterfaceIndex

Index of the interface

VcInboundLabel

Inbound label of the VC

VcOutboundLabel

Outbound label of the VC

SecondaryPw

Whether the PW is a secondary PW:
  • 1: The PW is a secondary PW.
  • 2: The PW is not a secondary PW.

InterfaceName

Name of the interface

SwitchVcId

ID of the switching VC

Impact on the System

PWE3 services are interrupted.

Possible Causes

Cause 1:

The LDP VC was manually deleted.

Cause 2:

L2VPN or MPLS was disabled.

Procedure

  1. This alarm is informational only, and no action is required.