Alarm Handling

S9300, S9300E, and S9300X V200R010C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
LSPM_1.3.6.1.4.1.2011.5.25.121.2.1.77 hwMplsTunnelCommitLost

LSPM_1.3.6.1.4.1.2011.5.25.121.2.1.77 hwMplsTunnelCommitLost

Description

LSPM/2/MplsTunnelCommitLost: OID [oid] The configurations of some MPLS TE tunnels were not committed. Related MPLS TE tunnels fail to go Up after the device is restarted.

The configuration of an MPLS TE tunnel was not committed. The MPLS TE tunnel will not go Up after the device is restarted.

Attribute

Alarm ID Alarm Severity Alarm Type

1.3.6.1.4.1.2011.5.25.121.2.1.77

Major

operationalViolation(8)

Parameters

Name Meaning

oid

Indicates the MIB object ID of the alarm.

Impact on the System

After the device saves the configurations and restarts, the MPLS TE tunnel fails to go Up.

Possible Causes

The configuration of an MPLS TE tunnel was not committed.

Procedure

  1. Check the configurations of all MPLS TE tunnels. Check whether some tunnel configurations are not committed based on service deployment information. Run the display current-configuration interface Tunnel command and find each tunnel interface on which the mpls te commit command is not run.
  2. Confirm whether the mpls te commit command needs to run to commit the configurations of each MPLS TE tunnel.

    • If the configuration needs to be committed, run the mpls te commit command on the tunnel interface and go to Step 3.
    • If the configuration does not need to be committed, go to Step 3.

  3. End.