Alarm Handling

S9300, S9300E, and S9300X V200R010C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
PM_1.3.6.1.4.1.2011.5.25.190.1.13.1 hwPMMeasureExceed

PM_1.3.6.1.4.1.2011.5.25.190.1.13.1 hwPMMeasureExceed

Description

PM/3/hwPMMeasureExceed:OID [OID] The number of statistical indexes has reached the upper limit.

The number of indicators had reached the upper limit.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.190.1.13.1 Minor

qualityOfServiceAlarm

Parameters

Name Meaning

OID

Indicates the MIB object ID of the alarm.

Impact on the System

The system will not be affected.

Possible Causes

The number of indicators had reached the upper limit.

Procedure

  1. Run the display this command in the PM view to check current statistical tasks and bound instances.
  2. Run one or more of the following commands to reduce performance statistics on the device:

    • Run the undo statistics-task task-name command to delete an unwanted statistical task.
    • Run the undo binding instance-type instance-type instance-type { all | instance { instance-name } & <1-5> } command to delete unwanted performance instances bound to a specified statistical task.
    • Run the measure disable [ measure-name ] command to disable unwanted measurement indicators in a statistical task.

Related Information

None

Translation