Alarm Handling

S9300, S9300E, and S9300X V200R010C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
CSSM_1.3.6.1.4.1.2011.5.25.183.3.3.2.3 hwCssSwitchOver

CSSM_1.3.6.1.4.1.2011.5.25.183.3.3.2.3 hwCssSwitchOver

Description

CSSM/4/SWITCHOVER: OID [OID] CSS switchover is complete. The new master chassis ID is [INTEGER].

An active/standby switchover occurs in the CSS.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.183.3.3.2.3 Warning equipmentAlarm(5)

Parameters

Name Meaning
INTEGER Indicates the chassis ID.

Impact on the System

Traffic processing capability of the CSS degrades.

Possible Causes

1:

The active/standby switchover is triggered by command line.

2:

The master device is reset due to a fault.

3:

The main control board of the master device is removed.

Procedure

  1. Check whether the active/standby switchover is performed by using the command line for a reason such as network maintenance.

    • If so, go to step 4.
    • If not, go to step 2.

  2. View the alarm information related to the master device's main control board. If the main control board has generated an alarm, the active/standby switchover is triggered by the master device's fault.

    • If the master device's main control board is faulty, rectify the fault.
    • If the master device's main control board functions properly, go to step 3.

  3. Check whether the main control board of the master device is removed.

    • If so, go to step 4.
    • If not, no action is required.

  4. Install the main control board and check whether the alarm is cleared.

    • If so, no action is required.
    • If not, collect alarm information and configuration information, and then contact technical support personnel.