Alarm Handling

S9300, S9300E, and S9300X V200R010C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
BASETRAP_1.3.6.1.4.1.2011.5.25.129.2.2.22 hwPowerInsufficiencyResume

BASETRAP_1.3.6.1.4.1.2011.5.25.129.2.2.22 hwPowerInsufficiencyResume

Description

BASETRAP/4/POWERLACKRESUME: OID [oid] The available power of the device is enough for the board. (Index=[INTEGER], Severity=[INTEGER], ProbableCause=[INTEGER], EventType=[INTEGER], PhysicalContainedIn=[INTEGER], PhysicalName="[OCTET]", EntityRatedPower=[INTEGER], DevAvailablePower=[INTEGER], DeviceTotalPower=[INTEGER])

This recovery notification is generated when the available power of the system is greater than the rated power of the board.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.129.2.2.22 Warning equipmentAlarm(5)

Parameters

Name Meaning
[oid] Indicates the ID of the MIB object.
Index Indicates the index of the entity. The entity in an alarm on power is a board.
Severity Indicates the severity level of the alarm.
ProbableCause Indicates the possible causes of the alarm. The codes of the possible causes are as follows:

533: IANAITUPROBABLECAUSE_POWERPROBLEMS indicates that the power module is faulty.

EventType Indicates the alarm type. Alarms are classified into the following types:
  • communicationsAlarm (2)
  • qualityOfServiceAlarm (3)
  • processingErrorAlarm (4)
  • equipmentAlarm (5)
  • environmentalAlarm (6)

This alarm is an alarm of the equipmentAlarm type.

PhysicalName Indicates the physical name of the entity.
PhysicalContainedIn Indicates the index of the parent entity of the alarm entity. In the alarm message, this parameter indicates the index of the slot where the power module is located.
EntityRatedPower Indicates the rated power of the board.
DevAvailablePower Indicates the available power of the system.
DeviceTotalPower Indicates the total power of the system.

Impact on the System

Services will be unaffected.

Possible Causes

The available power of the system is greater than the rated power of the board, meeting the power requirements of the board.

Procedure

  1. This is a normal notification and no action is required.