Alarm Handling

S9300, S9300E, and S9300X V200R010C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
IFNET_1.3.6.1.4.1.2011.5.25.41.3.32 hwIfControlFlapResume

IFNET_1.3.6.1.4.1.2011.5.25.41.3.32 hwIfControlFlapResume

Description

IFNET/4/IF_SUPPRESS_RESUME:OID [OID] The state of interface changed from suppress to unsuppress. (InterfaceIndex=[INTEGER], InterfaceExtIndex=[INTEGER], InterfaceName=[STRING], SuppressState=[INTEGER])

The flap control function was configured on an interface. An alarm was generated when the interface changed from the suppression status to non-suppression status.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.41.3.32 Warning communicationsAlarm(2)

Parameters

Name Meaning

OID

Indicates the MIB object ID of the alarm.

InterfaceIndex

Indicates the interface index.

InterfaceExtIndex

Indicates the extended interface index.

InterfaceName

Indicates the interface name.

SuppressState

Indicates whether the interface is suppressed.
  • 0: indicates the interface is unsuppressed.
  • 1: indicates the interface is suppressed.

Impact on the System

Services were restored to normal.

Possible Causes

The interface was in the suppression status. When the suppression penalty value of the interface reduced below the reuse threshold or the interface was deleted, the interface changed from the suppression status to non-suppression status. As a result, the alarm about that the interface restored the non-suppression status was generated.

Procedure

  1. This trap message is informational only, and no action is required.