Alarm Handling

S9300, S9300E, and S9300X V200R010C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
BASETRAP_1.3.6.1.4.1.2011.5.25.129.2.2.2 hwTempRisingResume

BASETRAP_1.3.6.1.4.1.2011.5.25.129.2.2.2 hwTempRisingResume

Description

BASETRAP/4/TEMRISINGRESUME: OID [oid] Temperature recovered to the normal range and the high temperature alarm was cleared. (Index=[INTEGER], BaseThresholdPhyIndex=[INTEGER], ThresholdType=[INTEGER], ThresholdIndex=[INTEGER], Severity=[INTEGER], ProbableCause=[INTEGER],EventType=[INTEGER], PhysicalName="[OCTET]", ThresholdValue=[INTEGER], ThresholdUnit=[INTEGER], ThresholdHighWarning=[INTEGER], ThresholdHighCritical= [INTEGER])

This recovery notification is generated when the temperature of the entity is reduced to the normal range.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.129.2.2.2 Warning environmentalAlarm(6)

Parameters

Name Meaning
[oid] Indicates the ID of the MIB object.
Index Indicates the index of the entity. The entity in the alarm message is a board.
BaseThresholdPhyIndex Indicates the index of the entity. The entity in an alarm on temperature can be a board, fan, or power module.
ThresholdType Indicates the type of the threshold that triggers the alarm. The threshold types are classified into the following:

1) temperatureSensor: temperature sensor

2) humiditySensor: humidity sensor

3) voltageSensor: voltage sensor

4) currentSensor: current sensor

5) powerSensor: power sensor

6) portTraffic: traffic of the port

7) portCrcError: CRC check of the port

8) portBroadcast: port broadcast

This alarm is triggered by the threshold of the temperature sensor.

Severity Indicates the severity level of the alarm.
ProbableCause Indicates the possible causes of the alarm. The codes of the possible causes are as follows:

130: IANAITUPROBABLECAUSE_lowTemperatue indicates that temperature is reduced.

EventType Indicates the alarm type. Alarms are classified into the following types:
  • communicationsAlarm (2)
  • qualityOfServiceAlarm (3)
  • processingErrorAlarm (4)
  • equipmentAlarm (5)
  • environmentalAlarm (6)

This alarm is an alarm of the environmentalAlarm type.

PhysicalName Indicates the physical name of the entity.
ThresholdIndex Indicates the subindex of the entity where the alarm is generated. A subindex identifies a temperature sensor when a board contains multiple temperature sensors.
ThresholdValue Indicates the current temperature. You can run the display temperature all command to view the temperature of the current board.
ThresholdUnit Indicates the unit of the temperature. The unit is as follows:

2: THRESHOLDUNIT_CENTIGRADE1 indicates that the temperature is expressed in centigrade.

ThresholdHighWarning Indicates the temperature threshold that triggers a minor alarm. The temperature threshold is determined by the hardware characteristics of the sensor. You can run the display temperature all command to view the threshold of the sensor on a board.
ThresholdHighCritical Indicates the temperature threshold that triggers a critical alarm. Currently, the value of this parameter is the same as the value of ThresholdHighWarning.

Impact on the System

None.

Possible Causes

An alarm is generated when the temperature of the entity exceeds the upper threshold of the sensor. In this case, you can take cooling measures to make the temperature lower than the upper threshold allowed by the sensor.

Procedure

  1. This is a normal notification and no action is required.