No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Alarm Handling

S9300, S9300E, and S9300X V200R010C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ENTITYTRAP_1.3.6.1.4.1.2011.5.25.219.2.2.3 hwBoardFail 132171

ENTITYTRAP_1.3.6.1.4.1.2011.5.25.219.2.2.3 hwBoardFail 132171

Description

ENTITYTRAP/2/BOARDFAIL: OID [oid] Board become failure for some reason. (Index=[INTEGER], EntityPhysicalIndex=[INTEGER], PhysicalName="[OCTET]", EntityTrapEntType=[INTEGER], EntityTrapFaultID=[INTEGER], EntityTrapReasonDescr="[OCTET]")

Some functions on a card failed.

NOTE:

Only EE series cards generate this alarm.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.219.2.2.3 Major equipmentAlarm(5)

Parameters

Name Meaning
OID Indicates the ID of a MIB object.
Index Indicates the index.
EntityPhysicalIndex Indicates the physical entity index.
PhysicalName Indicates the physical entity name.
EntityTrapEntType Indicates the physical entity type.
EntityTrapFaultID Indicates the alarm error code.
EntityTrapReasonDescr Indicates the reason description of the alarm.

Impact on the System

The card may not work or some of its functions are unavailable. Services on the card may be interrupted.

Possible Causes

The ambient temperature exceeds 45°C.

Procedure

  1. Open an air-conditioner and enhance heat dissipation to reduce the ambient temperature within 45°C.