Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ENTITYTRAP_1.3.6.1.4.1.2011.5.25.219.2.6.1 hwFanRemove 137216

ENTITYTRAP_1.3.6.1.4.1.2011.5.25.219.2.6.1 hwFanRemove 137216

Description

ENTITYTRAP/4/FANREMOVE: OID [oid] Fan has been removed. (Index=[INTEGER], EntityPhysicalIndex=[INTEGER], PhysicalName="[OCTET]", EntityTrapFaultID=[INTEGER])

The fan is not installed properly.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.219.2.6.1 Warning equipmentAlarm(5)

Parameters

Name Meaning
OID Indicates the ID of the MIB object.
Index Indicates the index.
EntityPhysicalIndex Indicates the index of the physical entity.
PhysicalName Indicates the name of the physical entity.
EntityTrapFaultID Indicates the error code.

Impact on the System

The temperature of the device will increase due to deterioration of heat dissipation performance. Services are not affected in a short time, but the fault should be rectified quickly.

Possible Causes

The fan was removed or not installed properly.

Procedure

  1. Check whether the fan was manually removed for routine maintenance.

    • If so, the alarm handling ends.
    • If not, go to step 2.

  2. Run the display device command to check whether the fan is registered successfully.

    • If so, collect alarm information and configuration information, and then contact technical support personnel.
    • If not, go to step 3.

  3. Check whether the fan is installed securely.

    • If so, collect alarm information and configuration information, and then contact technical support personnel.
    • If not, install the fan securely and go to step 4.

  4. Check whether there is an alarm indicating that a fan is installed.

    • If so, the alarm handling ends.
    • If not, collect alarm information and configuration information, and then contact technical support personnel.