Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
RSVP_1.3.6.1.4.1.2011.5.25.148.1.12.2.5 hwRsvpTeIfNbrThresholdExceed

RSVP_1.3.6.1.4.1.2011.5.25.148.1.12.2.5 hwRsvpTeIfNbrThresholdExceed

Description

RSVP/3/RSVPIFNBRTHRESHOLDEXCEED: OID [oid] The number of RSVP neighbors exceeded the threshold. (hwRsvpTeIfName=[octet], hwRsvpTeIfNbrCurrentCount=[integer], hwRsvpTeIfNbrThreshold=[integer], hwRsvpTeIfNbrTotalCount=[integer])

The proportion of configured RSVP neighbors to all supported ones reached the upper alarm threshold.

Attribute

Alarm ID Alarm Severity Alarm Type

1.3.6.1.4.1.2011.5.25.148.1.12.2.5

Minor

qualityOfServiceAlarm(3)

Parameters

Name Meaning

oid

Indicates the MIB object ID of the alarm.

hwRsvpTeIfName

Name of an RSVP interface

hwRsvpTeIfNbrCurrentCount

Number of existing RSVP neighbors

hwRsvpTeIfNbrThreshold

Threshold (percent) of RSVP neighbors that device supports

hwRsvpTeIfNbrTotalCount

Maximum number of RSVP neighbors that a device supports

Impact on the System

If new RSVP neighbors are created after the proportion of configured RSVP neighbors to all supported ones on a specified interface has reached the upper alarm threshold, services may be affected.

Possible Causes

The proportion of configured RSVP neighbors to all supported ones on a specified interface reached the upper threshold.

Procedure

  1. Check the hwRsvpTeIfName field and obtain information about the interface on which the alarm is generated.
  2. Check whether hwRsvpTeIfNbrThreshold is set in a specified range. (Setting hwRsvpTeIfNbrThreshold to 80% of hwRsvpTeIfNbrTotalCount is recommended. A smaller value leads to useless threshold-crossing alarms to be generated.)
    • If the value is within the specified range, go to Step 4.
    • If the value is out of the specified range, go to Step 3.
  3. Run the mpls rsvp-peer-number threshold-alarm upper-limit upper-limit-value lower-limit lower-limit-value command to set the alarm threshold. Then check whether the alarm is cleared.
    • If the alarm is cleared, go to Step 6.
    • If the alarm persists, go to Step 4.
  4. Run the undo mpls rsvp-te command in the interface view to delete unwanted RSVP interface configurations or delete unwanted RSVP interface configurations on the peer interface to reduce the number of RSVP neighbors. Then check whether the alarm is cleared.
    • If the alarm is cleared, go to Step 6.
    • If the alarm persists, go to Step 5.
  5. Collect alarm information and configuration information, and then contact technical support personnel.
  6. End.