Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
L2V_1.3.6.1.4.1.2011.5.25.119.3.2.2 hwCCCVcUp

L2V_1.3.6.1.4.1.2011.5.25.119.3.2.2 hwCCCVcUp

Description

L2V/3/CCCVC_UP_T:OID [oid] The status of the CCC VC turned UP. (CccName=[STRING], InterfaceIndex=[INTEGER], InterfaceIndex=[INTEGER], HWL2VpnStateChangeReason=[INTEGER], InterfaceName=[STRING])

The trap was generated when the CCC VC was Up.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.119.3.2.2

Minor

other(1)

Parameters

Name Meaning

oid

Indicates the MIB object ID of the alarm.

CccName

Indicates the name of the CCC connection.

InterfaceIndex

Index of the interface used as the table index.

InterfaceIndex

Index of the interface reported to the network management system as a parameter.

HWL2VpnStateChangeReason

Indicates the cause of the VC status change. For details, refer to hwCCCVcStateChangeReason in the appendix of HUAWEI-CCC-MIB.

InterfaceName

Indicates the interface name.

Impact on the System

The CCC service will be recovered.

Possible Causes

1.

The trap was generated when a VC became Up.

2.

The configuration was modified. For example, the next hop address of the CCC was changed.

Procedure

  1. Check whether the service is restored.

    • If so, it indicates that the trap message is informational only, and no action is required.
    • If not, go to Step 2.

  2. Check whether the current configuration is the same as the original configuration. For example, check whether the next hop address of the CCC is the same as the address of the peer interface of the outbound interface.

    • If so, go to Step 4.
    • If not, go to Step 3.

  3. Restore the original configuration and check whether the alarm is cleared.

    • If the alarm is cleared, go to Step 5.
    • If the trap is no cleared, go to Step 4.

  4. Collect alarm information and configuration information, and then contact technical support personnel.
  5. End.